Examples of products tested and / or certified by AFTRL are Foams, Powders & Gases agent solid fuel- burning appliances ; fire doors and frames; door hardware; fire-rated wall assemblies; wood trusses; prefabricated construction; specialty wood products; structural laminated timber products; fire-resistant paints and floor / ceiling fire-rated assemblies for physical  chemical properties, fire performance  Portable & Mobile Fire Extinguisher for Mechanical strength, Hydrostatic & Fire ratings, Hose & hose-reel.

 
Details of Testing Items
Testing Item Reference Standards Equipment
Foam concentrate for producing Mechanical Foam for Fire Fighting viz. AFFF, Protein Foam, Film Forming Fluoro Protein Foam & Synthetic Foam IS: 4989;2006

Detail of testing parameters
Multipurpose Aqueous film forming foam liquid concentrates for extinguishing Hydrocarbon & Polar solvent fires IS: 4989 (Part – 4);2003
Aqueous film forming foam (AFFF), Protein foam, Fluoro Protein for both Hydrocarbon & Polar Fuel group   UL – 162;1999
Dry Chemical Powders for Fighting B & C Class fires IS:4308;2003

Detail of testing parameters
Dry Chemical Powders for fighting A,B,C Class fires IS:14609;1999
Dry Powder for fighting fires in Burning metals IS:4861;1984
Dry Chemical Fire Extinguishers UL-299C;2009
Portable Fire Extinguishers – Performance & construction IS:15683;2006

Detail of testing parameters
Fire fighting portable fire extinguishers-Performance and construction ISO 7165:2009
Portable fire extinguishers Part-7, Characteristics performance measurement & test method EN 3-7;2007-10
Rating and fire testing of fire extinguishers UL-711;2004
Wheeled fire Extinguishers IS:16018;2012

Detail of testing parameters
Mobile fire extinguishers – Part-1:characteristics performance and test method DIN EN 1866-1;2007-10
Gas Cartridges for use in Fire Extinguishers  IS: 4947;2006

Detail of testing parameters
Specification for non-percolating flexible fire fighting delivery hose IS:636;1988


Detail of testing parameters
Controlled percolating hose for fire fighting – specification IS:8423-1994
Thermoplastic Hoses (Textile Reinforced) for water – General Purpose IS:12585;1988
Unlined flax canvas hose fire fighting IS:4927;1992
Landing valves  IS:5290-1993

Detail of testing parameters
First –Aid hose –reel for fire fighting IS:884 -1985

Detail of testing parameters
Specification for Hydrant stand –pipe for fire fighting IS:5714-1981

Detail of testing parameters
Specification for couplings, double male and double female instantaneous pattern for fire fighting IS:901-1988

Detail of testing parameters
Suction hose couplings for fire fighting purpose –specification IS: 902-1992  
Fire Hose delivery coupling Branch Pipe, Nozzles and Nozzle Spanner - Specification IS:903;1993

Detail of testing parameters     Top
Specification for 2 –WAY and 3-WAY suction collecting heads for fire fighting purposes IS:904 – 1983

Detail of testing parameters
Specification for delivery breeching, dividing and collecting, instantaneous pattern, for fire fighting purposes IS: 905 – 1980

Detail of testing parameters
Specification for Revolving branch pipe for fire fighting IS:906 :1988

Detail of testing parameters
Fire Hydrant, Stand Post Type IS: 908;1975

Detail of testing parameters
Specification for Couplings, Branch pipe, nozzle used in hose reel tubing for fire fighting IS:8090 – 1976

Detail of testing parameters
Specification for branch pipe, universal, for fire fighting purposes IS:2871 – 1983

Detail of testing parameters
Fire Hooks IS: 927- 1981

Detail of testing parameters
Fireman’s axe IS: 926;1985

Detail of testing parameters
Fire beaters IS: 8096;1992

Detail of testing parameters
Fire blanket IS:15381;2003

Detail of testing parameters
Specification for Galvanized Mild Steel Fire Bucket IS:2546;1974

Detail of testing parameters
FUNCTIONAL REQUIREMENTS FOR 275 L/MIN PORTABLE PUMP SET FOR FIRE FIGHTING IS:942:1982

Detail of testing parameters
FUNCTIONAL REQUIREMENTS FOR 680- l/min TRAILER PUMP FOR FIRE BRIGADE USE IS:943:1979
FUNCTIONAL REQUIREMENTS OF 1800 – l/min TRAILER PUMP FOR FIRE BRIGADE USE IS:944:1979  
Functional
requirements for water tender type ’a’ for fire brigade use
IS:948;1983

Detail of testing parameters
Emergency (rescue) tender – functional requirements IS:949;2012
Functional requirements for water tender, type b for fire brigade use IS:950;2012  


Functional requirements for crash fire tender for air fields
IS:951;2003
Nozzle for fire brigade use IS:952;1986

Detail of testing parameters
 
 
 